Research Article: Validation of a headspace gas chromatography-flame ionization detector (HS GC-FID) method for determination of terpinen-4-ol in volatile oil from Zingiber montanum rhizome
Author: Nirawan Kitprapiumpon, Shinnawat Saengungsumalee, Thitaree Theerachayanan, and Surapote Waongyai
Email: shinnawat@siam.edu
Department/Faculty: Faculty of Pharmacy,  Siam University, Bangkok 10160
Published/แหล่งเผยแพร่: RSU International Research Conference 2021 on Science and Technology

Citation

Nirawan Kitprapiumpon, Shinnawat Saengungsumalee, Thitaree Theerachayanan, and Surapote Waongyai. (2021). Validation of a headspace gas chromatography-flame ionization detector (HS GC-FID) method for determination of terpinen-4-ol in volatile oil from Zingiber montanum rhizome. In The 6th International Conference on Sciences and Technology (RSUSCI-2021) (pp.27-36). Pathum Thani: Rangsit University.


ABSTRACT

This study aimed to develop a headspace GC-FID method for the analysis of terpinen-4-ol in Zingiber montanum (Plai) essential oil. The volatile oil was extracted from fresh Z. montanum rhizomes by steam distillation. The amount of terpinen-4-ol was determined by a headspace gas  chromatography-flame ionization detector (HS GC-FID) method using benzyl alcohol as an internal standard. The developed method was validated according to the parameters recommended by the International Conference on Harmonization (ICH). Linearity was accessed across the concentration range of 2.5 – 15 µL/mL. The plot of the peak area ratio versus the concentration provided a good linear of this method with a correlation coefficient (r2) of 0.9989. The LOD and LOQ were found to be 0.20 and 2.5 µg/mL, respectively, which indicated a high sensitivity of the method. The instrument (n = 6), intra-day (n = 9), and inter-day (n = 3) precision as indicated by %RSD were 1.77, 1.73, and 1.77 %, respectively. The recoveries at 3 different levels of terpinen-4-ol were between 100.23 to 100.85%. The content of terpinen-4-ol in Plai essential oil was 15.53 ± 0.27 % v/v. The developed method can be used in routine analysis of Plai essential oil and its products in both cosmetic and pharmaceutical industries.

Keywords: Terpinen-4-ol, Zingiber montanum, Plai, Gas chromatography, Validation


Validation of a headspace gas chromatography-flame ionization detector (HS GC-FID) method for determination of terpinen-4-ol in volatile oil from Zingiber montanum rhizome

Faculty of Pharmacy, Siam University, Bangkok, Thailand

Related

Tags:
Was this article helpful? บทความนี้เป็นประโยชน์หรือไม่?
ไม่ / Dislike 0
Views: 182
Facebook
Twitter
LinkedIn
WhatsApp
Email
Print

QR code for article

QR Code